line-gene k real-time pcr detection system
 
 
 
Instruments
Consumables

 specifications


       
line-gene. k is the newest system in bioer's range of pcr detection systems. it features more advanced implementations of peltier and fiber optic technology and a new direct current power system.

the new instruments share the peltier effect and fiber optic design features that provide the exceptional accuracy and stability of the line-gene instruments.the new units offer improved uniformity,stability and accuracy by utilizing a constant-current power supply and an advanced multi-point temperature control module.the line-gene.k has improved temperature control and more uniform heating throughout the sample block to improve the accuracy of pcr detection.

the line-gene.k series is available in a range of automated and manual models with the ability to handle one, two, three or four combinations of excitation and emission wavelengths.


15 items(just for you!)
volume adaptation—software automatically adjusts heat exchange to differences in   sample volumes.
●new multipoint temperature monitoring allows more accurate and uniform temperature   control throughout the heating block.
●gradient function—creates a temperature gradient across the sample block. maximum   24℃ difference between row 1 and row 24.
●sample preservation—after completion of experiment, the system can automatically   refrigerate samples until they are moved to storage.
●use of direct current power supply improves thermal efficiency and reduces power   consumption by 30%.
●improved optics—greater efficiency in fiber optic system provides reduced signal to   noise ratio.
●automatic hot lid—provides constant pressure and software-managed temperature   control.
●configuration upgradable—manual versions of the instrument can be upgraded to   automatic. systems can be upgraded from 1 wavelength to 4 wavelengths.
●numerous data ports—choose from serial(rs 232),usb and ethernet connections for pc   data interface.
●multiple tube styles—the sample block will accept several styles of 0.2ml tubes   including 8-tube strips.
●data protection—system preserves experimental data if there is a power interruption   during operation.
●automatic amplitude adjustment—the instrument detects the fluorescence strength in   the samples and automatically adjusts to the correct system sensitivity.
●new software—a new generation of line-gene software provides even greater   convenience and more powerful functions.
●upload software instructions—define experiment instructions with easy-to-use   pc- based software,then upload to instrument.
●overheating protection—if the operating environment exceeds the temperature range   for operation within specification, the instrument will shut down.at 35℃the   instrument will sound a warning;it will turn off at 40℃.

interface introduction:

software:


snps detection
line-gene system is a multicolor fluorescence detection system and can carry out the detection analysis of snps.

two kinds of data analysis methods:


2nd derivative maximum:

this method automatically calculates the maximum second derivative value of every fluorescent curve and defines this value as the ct value.

fit points:
the user sets baseline and a threshold values then draws a threshold line.based on user instructions,the software will select a number of sample points on the fluorescence curve that are above baseline and in the logarithmic phase into a line.the intersection of this line with the threshold line is defined as the ct value.

specifications:

   model

fqd-48a(a4)
(a4: means automatic
lid and 4 channels)

fqd-48a(m2)
(m2: means manual
lid and 2 channels)

sample capacity

48×0.2ml

48×0.2ml

reaction system

10~100μl

10~100μl

dynamics range

10~1010copies

10~1010copies

max.channel number of
fluorescence detection

4 channels

2 channels

excitation light wavel
ength(450-590mm)

standard positioning:
f1:470nm f2:523nm
f3:543n  f4:571nm

f1:470nm f2:523nm

fluorescence detecting
wavelength(500-630nm)

standard positioning:
f1:525nm f2:564nm
f3:584n  f4:612nm

f1:525nm f2:564nm

detecting fluorescence

fam,sybr green i,hex,vic,tamra,
tex red,rox

fam,sybr greenⅰ,hex

temp. range

4℃~99.9℃

4℃~99.9℃

heating rate(max)

≥4.0℃/sec

≥4.0℃/sec

cooling rate

≥4.0℃/sec

≥4.0℃/sec

temp. uniformity of block

≤±0.3℃

≤±0.3℃

temp. control accuracy

≤±0.1℃

≤±0.1℃

gradient temp. range

1℃~24℃

1℃~24℃

hot-lid temp. range

80℃~120℃

80℃~120℃

operation system

windows 2000/xp

windows 2000/xp

power supply

ac220v 50hz 500w

ac220v 50hz 500w

dimension(mm)

520×450×320(l×w×h)

520×450×320(l×w×h)

net weight

25kg(without computer)

25kg(without computer)



 