Home  |  About us  | Support  | News |Contact    中文  
Life Science Reagents
constant temperature baths
 
 
 
Water Bath Series

 specifications


·introduction

the constant temperature bath is comprised of a bath and a high precision thermostat which combines the microprocessor and the pid technique.
the constant temperature bath widely used in industries such as petroleum, chemical, medicine, biochemistry, metrology and other light industries and scientific research etc.

·features

·control panel
digital display,easy setting and operating,adjustable temperature,alarm signal display.
·advanced thermostatic controller
high temperature control accuracy up to 0.02.wide temperature control range,temperature controlling and setting at will in the range of 10-95 at room temperature.
·circulation system
the bath is fitted with a powerful jet-pump for agitating and has joints connected with the external circulation system through which the liquid inside the bath can be exported to an outside apparatus to thermostatically control the external circulation. similarly, inside the bath are separate circulating pipes through which the liquid used by the external experiment is circulated to enable thermostatic control without mixing with the liquid in the bath.

·safety features

low liquid level protection

if the water level is too low the heating pipe will shut off and the alarm light will illuminate.

temperature out of control

if the temperature exceeds the preset level by 2℃ during the thermostatic process the heating pipe will shut off and the alarm light will illuminate.

over current protection

if the electrical current is exceeded during the course of operation the internal fuse will blow thereby protecting the apparatus and the operator.

external sensor
  external circulator
·equipped with an outside connector by which the external circulation can be controlled.
·with free control options of the internal and external circulation the device can meet customers demands.

 

 
  ·specifications
 

型 号参 数

n1 - 2c

temp. control range

( room temperature + 10 ℃~ 95 ℃)

temp. control accuracy

± 0.02 ℃ ( water temperature 40 ℃)

heater

1000 w

heater time

< 80 min (from room temperature20 ℃ to 95 ℃ )

input a.c. voltage

ac220 ± 22v 50 ± 1hz

input power

1100 w

insulation resistor

≥ 1.5 m w

dielectric intensity

tested by ac voltage of 50hz,sine wave, 1500v for 1 minute, no flashover detected.

internal dimension

(l×w×h)(mm)

130× 95×170 ( l ×w ×h )

bath liner dimension

(l×w×h)(mm)

260×160×170 ( l× w×h )

dimension

(l×w×h)(mm)

420×234×428 ( l ×w×h )

external circulation

the jet and circumfluence hole diameter: ?10mm

cooling pipe interface dimension

ф10mm

net weight

15 kg